PPL IMP 2035A
POSSIBLES COMBINATIONS (6, 10, 12 zones)
LED indicator
zone
Screw connector for
power supply
MASTER 6 ZONES + SLAVE 6 ZONES + TIMER
MASTER 6 ZONES
+ TIMER
MASTER 6 ZONES + SLAVE 4 ZONES + TIMER
Screw connector fo
r
pump and accessories
Supply fo
r
thermostat
and actuators for 1
zone
Green: - Heating indication (water circulation on this zone)
Operating temperature
0°C - 50°C
Protection
Class I - IP20
Power supply
230 VAC +/- 10%
Output
Pump & accessories:
Relay => 2 free contact 8A 250Vac
Zones:
6 independent zones => the maximum output
power of each zones depends on thermostat
connecting on this zone.
Master 6 zones 230VAC for NC actuators (normaly closed)
USER GUIDE
TECHNICAL CHARACTERISTICS
FUNCTION and DESCRIPTION
LED INDICATOR
GB
The MASTER with 6 zones is a wiring module with built in pump logic. All the
main electrical connections for water floor heating system are existing. This
box can be adapted either on a DIN rail or directly on a wall. (the DIN rail
mounting permit to add with facility a SLAVE module or TIMER). It connects
room thermostats to their corresponding actuators. The state of the zones are
indicated by individual LEDs. By using terminal A and B, the pilot wire of
thermostats can be controlled by an external TIMER. As soon as we have a
heat demand from one zone a relay with 2 potential-free contacts is switch on
(pump, boiler or other possible connection).